Witech Micropod2 Clone Registration Error (Solved)

Here's the working solution to wiTech Micropod 2 clone Chrysler diagnostic tool registration problem.


Error:
"Registration is needed
Device with serial number*** is not registered. Please check the knowledge
base to determine how to register a device"
witech-register-device-error

Obdii365.com engineer solution:

Right click wiTech Diagnostic Application-> Properties->Open file location
solve-witech-register-error-1
C:/Program Files (x86)/DCC Tools/wiTECH/client
solve-witech-register-error-2

Open app-config text file
solve-witech-register-error-3
Change the first number to any value marked red above. 
i.e change 6 to other numbers, 1-9
Then save the text file. (Very important!!!)

Run Witech Micropod II software again
If witech still prompts  error " an internal registration error has occurred ", just ignore by clicking no icon to close it.
solve-witech-register-error-4

Problem solved.
Then tick “Offline” on the bottom left corner (Don’t need to login)
Run diagnostic software.
solve-witech-register-error-5
Video guide:
How to solve Witech Micropod 2 registration error
www.obdii365.com

2018/10/25

Free Download DRB III Emulator for Micropod 2 clone

Free download DRB III Emulator on Mega:
download-drb-iii-emulator
DRB III Emulator is the exact scan tool software application used in Chrysler, Jeep, and Dodge dealerships to service non-CAN based vehicles from 1998-2007. The DRB III Emulator software application now runs on your personal computer and interfaces with our custom DRB III+ hardware device to enable all the functions of the original Chrysler DRB III Scan Tool and more. This software package even comes with non-powertrain ECU programming files to enable reflashing everything from BCMs to sliding door modules.

IMPORTANT: You can get DRBIII Emulator, DRBIII Enhanced Emulator setup and U-Scan Chrysler.
But no one holds responsibility of any risk you’ll take when using free DRBIII emulator software.

For security, you’re advised to the tested version sw with your Micropod 2 clone:


DRBIII Emulator Install:

For using DRBIII Emulator software with tools like VCI pod or Micropod II with witech version 14.xx.xx – 17.xx.xx, it depends on your device (clone or orig / old or newer release) and ONLY AFTER that, install DRBIII Emulator.
Watch screenshot.
install-drb3
Here is a step-by-step tutorial of DRBIII emulator on Micropod 2 clone:


DRB III Emulator Review: works on Micropod 2

I managed to make the Enhanced DRB III Emulator work with a micropod 2 clone on V17.04.27 Witech with Windows 7 32 bits all offline mode and no subscription.
First install Witech then install the DRB emulator and then the enhanced one.
find it here : C:\ProgramData\wiTECH\jserver\data\core\stubs
Or use the files provided in first post
Afterwards plug usb in pod then pod in the car turn ignition to on position and at last in the laptop
Open web browser, i used firefox and in the address bar put this and press enter : http://localhost:9876/launchExternalApp?appName=drb_iii_enhanced_emulator&locale=eng_ENG&deviceIp=172.22.22.22
It will launch the enhanced emulator.

DRB 3 Emulator Car List:

DRB 3 supports Chrysler, Jeep, and Dodge dealerships to service non-CAN based vehicles from 1998-2007 with protocols incl.
SAE J1850 PWM (FORD)
SAE J1850 VPW
SAE J2610 SCI (CHRYSLER)
ISO 15765 (Network Transport Protocol)
ISO 11898 (High Speed CAN)
ISO 14230 (Keyword2000)
ISO 9141/9141-2 (K-Line)
Chrysler Collision Detection Bus (CCD)
drb-iii-car-list

How to install wiTech MicroPod 2 V17.04.27 software on Win7

Free download wiTech MicroPod 2 V17.04.27 Chrysler Jeep Dodge diagnostic software crack, then install on windows 7 32 bit or 64 bit for use.


wiTech 17.04.17 software crack download on Mega: worked on windows 7 32 bit or 64 bit
wiTech 17.04.17 java air download: necessary used with wiTech software v17

wiTech software v17.04.17 only work with MicroPod 2 clone with item no.sp271-c:
micropod2-clone
wiTech MicroPod system requirement:

Recommended hardware:
System type: laptop or tablet
Processor: intel i7 – 630M dual core 2.66GHz or better
HDD space: 80GB
Memory: 4GB
Operation system: Windows 7 professional 32 bit or 64 bit
Network adapter: 10/100 wired, 802.22g wireless
Monitor: 1920*1080 resolution

Minimum hardware:
System type: laptop or tablet
Processor: intel i5 – 520M dual core 2.4GHz or equivalent
HDD space: 40GB
Memory: 2GB
Operation system: Windows 7 professional 32 bit or 64 bit
Network adapter: 10/100 wired, 802.22g wireless
Monitor: 1024*768 resolution

Software:
Adobe air: version 3.10 or newer
Java: 1.6.0_21 or newer
Adobe reader: 9.0 or newer
Internet explorer: 8.0 or newer
SVG viewer: 3.0
wiTech MicroPod 2 V17.04.27 Windows 7 32/64bit install:
Open disk E: wiTech V17.04.27, then read the PDF “readme”, wiTech MicroPod II installation manual attached
install-v17-04-27-witech-1
First, install AdobeAIRInstaller.exeAccept the agreement
Installing…
Adobe air installation completed.
install-v17-04-27-witech-2
Second, Install jre-6u45-windows-i586.exe(Update Later: an update to Adobe air)
Click on Install to accept the lience agreement
Installing Java…
Have successfully installed Java
install-v17-04-27-witech-3
Third, install wiTECH_Install_17.04.27.exeselect a setup language
install-v17-04-27-witech-4
wiTECH system requires the following items installed on your computer:
Microsoft visual c++ 2010 or later redistributable package (x86)
Enlang 5.8.4.2
Java standard edition 7 update 25
install-v17-04-27-witech-5
Installing wiTECH…
install-v17-04-27-witech-6
install-v17-04-27-witech-7

install-v17-04-27-witech-8

install-v17-04-27-witech-9
install-v17-04-27-witech-10
install-v17-04-27-witech-11
Have successfully installed wiTECH 17.04.27

Windows security alert: allow access

Fourth Restart the computer

Installing device driver software…
Local network connection: work network
Device is ready for use
install-v17-04-27-witech-12
Setup in driver Computer management: select CDCECM Ethernet Adapter
install-v17-04-27-witech-13

WARNING for MicroPod 2 Setup:
1 The computer on the day of the date
2 The computer must be connected to the Internet
3 Connect the machine to the device and open the Chrysler wiTECH software
Done!

Now, wiTECH diagnostic application is ready for use.

It’s wiTECH version 17.04.27
install-v17-04-27-witech-14
wiTech MicroPod II login: no need user id and password
wiTECH 17.04.27 works offline
install-v17-04-27-witech-15
wiTECH 17.04.27 supports 2017 models
install-v17-04-27-witech-16
Vehicle id: 2017 WD, has been successfully identified
install-v17-04-27-witech-17
Go to vehicle diagnostics and programming.
install-v17-04-27-witech-18
Enjoy!

Why wiTech Micropod 2 SP271-C1 is the best clone?

This is for those who are looking for a decent wiTech Micropod 2 China clone.
witech-micropod2

It’s the best quality of Micropod 2 clone SP271-C1, quality as good as VCM2 clone SP177-C1.

BUT, WHY IT IS THE BEST QUALITY MICROPOD 2 FROM CHINA?

First, this Micropod 2 SP271-C1 can be connected to the NETWORK and NEVER LOCKED!

You could use the clone for ONLINE DIAGNOSIS for NEW CHRYSLER CARS.
If you have an account, you also are able to do ONLINE PROGRAMMING.

Second, the wiTech Micropod2 SP271-C1 is confirmed to WORK NO ISSUES WITH DRBIII EMULATOR as well as the original Micropod 2.

This is a test report from our customer @rcompart and it’s verified to get DRBIII with the clone Micropod 2. And, it’s kind of him share the tutorial in detail with you guys.
All can be found here:

With DRBIII emulator, you can have your Micropod 2 for old Chysler the year 1997 – 2004 (2005)
Without DRBIII, Micropod 2 clone only works for Chrysler made after the year 2003


That is, you have a way for old Chrysler with a cloned Micropod 2 unit.


Third, wiTech software is confirmed also no issues with this Micropod2.
It’s tested 100% by real professionals working for obdii365.com

Note: what is DRB3 and what’s wiTech? What’s the main difference The DRB3 emulator is part of Chrysler’s Witech software. The Witech software supports two different pass-through devices, The VCI pod which is sold with the Witech system and the Chrysler Starmobile. The DRB3 emulator is a convenience item for dealerships to allow the use of their current witech scan-tool on older non CAN bus vehicles. It is not by any means a cost saving option.

The last, PCB talks a lot

That’s all. Hope it’s helpful to you all.

2018/10/24

Free Download wiTech MicroPod2 V17.04.27 Software

Chrysler Jeep Dodge diagnostic tool wiTech MicroPod II software released to new version V17.04.27 on July 2017.
witech-micropod2-v17
1. Latest Software: V17.04.27
2. Multi-Language: English, French, Spanish, German, Italian, Russian, Japanese, Korean and Chinese
3. PC-Based: Requires PC connection
4. Must connect to network to work, otherwise will prompt you to activate software.
5. Operating System: Windows XP/Windows 7
Using Tips (Important): Network connection needed.
First connect MicroPodII to vehicle, if the red indicator turns on, then connect to laptop and run software.


wiTECH MicroPOD2 features:
* Supports all the latest technologies and vehicle platforms including the latest Chrysler and Fiat Vehicles.
* Works as a direct replacement for the wiTECH POD.

wiTECH MicroPOD 2 model year coverage:

Although small in stature, this dongle-style device offers 100% CAN – equipped coverage to 2016 for Chrysler, Dodge, Jeep, and Fiat vehicle platforms.

wiTECH Software function: 

1) It can be used as diagnostic and programming tool by the dealerships. Replaces your StarMobile, StarScan, and wi-TECH POD,provides world-class diagnostic services to your customers.
2) A separate Tech Authority  Subscription is required to access to Module Re-Flash Programming, TSBs, wiring diagrams, and repair information.

Tips on Setting up Witech V17 on Windows 7 Operating system:
System requirement:
witech-micropod2--system
Installation Tips:
 
1   installation  AdobeAIRInstaller.exe
2   installation  jre-6u45-windows-i586.exe
3   installation  wiTECH_Install_17.04.27.exe
4.  Restart the computerWARNING;   1. The computer on the day of the date
2. The computer must be connected to the Internet
3. Connect the machine to the device to open the software

How to solve wiTech MicroPod2 Wiring Diagram NOT Working

For newbies: problem and solutions of how to use wiTech MicroPod 2 Chrysler Jeep Dodge diagnostic tool Wiring Diagram, incl.
1: Wiring Diagrams Not Loading/Rendering
2: Unable to View Wiring Diagram or Service Information


Part 1: wiTech Wiring Diagrams Not Loading/Rendering

ISSUE SUMMARY: Wiring Diagrams Not Loading / Rendering
DESCRIPTION:
  • Users may experience
    • Slowness or no rendering of wiring diagrams, component details, and location views through the application launched from TechCONNECT.
    • Table of Content (ToC) may not load or application may display error:
      • “The application has encountered an error. For assistance, please call the Help Desk at 1-888-wiTECH-1.”
    • Look for keywords of dealer personal reporting issues about not being able to load wiring diagrams for any vehicles 2010 or newer.
    • Any 2009 and previous vehicles should be directed to the TechCONNECT HD at 800.374.4040 (US and Canada).
NOTE: The following OS/browser combinations are supported for DealerCONNECT:
  • Windows 7 Professional: 32-bit/64bit with IE9, IE10 using the 32-bit built-in browser
PROCEDURE:
  • A higher performance version of the wiring application (identical in features and content) exists at https://wiring.dcctools.com. AKA Wiring Diagram External Site.
  • If you are experiencing performance issues, we recommend you use this equivalent website which accepts the same login credentials as DealerCONNECT.
NOTE: External site vehicle information and application features are updated more frequently than TechCONNECT application.
NOTE: The External site supports all major browsers including IE, Chrome, Firefox, & Safari.
POLICY:
  • The DealerCONNECT Help Desk http://www.obdii365.com/ provides assistance with viewing issues in the TechCONNECT and Service Information application 2009MY or older platforms.
  • The Wiring Help Desk provides assistance with application and data issues with the New Wiring Diagram Application covering 2010MY and newer platforms.
  • NOTE: The following OS/browser combinations are supported for wiring diagram usage:
    • Windows 7 Professional: 32-bit/64bit with IE9, or newer using the 32-bit built-in browser
    • Windows XP Professional: IE8 with Adobe SVG Viewer plugin version 3.03.
* Microsoft no longer supports Windows XP, troubleshooting support is not provided to Windows XP machines with OS errors.

Part 2: wiTech Unable to View Wiring Diagram or Service Information



ISSUE SUMMARY: Unable to view Wiring Diagram or Service Information
DESCRIPTION:
  • When attempting to view Wiring Diagrams through the Wiring Diagram application or Service Information through TechCONNECT, users may experience a blank screen with no information.
POLICY:
  • The Wiring Help Desk provides assistance with application and data issues with the New Wiring Diagram Application covering 2010MY and newer platforms.
  • NOTE: The following PC/browser combinations can be used to view wiring diagram:
    • Windows 7 Professional: 32-bit/64bit with IE9 using the 32-bit built-in browser
    • Windows XP Professional: IE8 with Adobe SVG Viewer plugin version 3.03.
  • The DealerCONNECT Help Desk http://www.obdii365.com/ provides assistance with viewing issues in the TechCONNECT and Service Information application 2009MY or older platforms.
  • NOTE:  For up to date DealerCONNECT browsers, please contact the DealerCONNECT Help Desk.
* Microsoft no longer supports Windows XP, troubleshooting support is not provided to Windows XP machines with OS errors.


PROCEDURE:
Follow the correct procedure for your PC’s operating system below:
Windows 7 64-bit:
NOTE: This issue is experienced more on the TechCONNECT and Service Information application (2009 MY and previous).
If you are experiencing this issue with the TechCONNECT and Service Information application and this KB does not resolve your issue, please contact DealerCONNECT Help Desk http://www.obdii365.com/for further assistance.
User will see the following error: Blank Page with “Red X” icon on the top left hand corner of the page.
witech-wiring-diagram-not-view-1
witech-wiring-diagram-not-view-2
  1. IE 9 has a built-in SVG viewer and does not require the installation of the SVG viewer plug-in.
  2. This error occurs when running the IE 9 64-bit version.
    1. SVG images are not rendered correctly on this version; please verify you are using IE 9 32-bit version.
witech-wiring-diagram-not-view-3
  1. To reveal what version of IE 9 you are running, open IE and navigate to Help About Internet Explorer
  2. You can also confirm that you have launched the IE 9 32-bit by searching for Internet Explorer 9.
  • Select Start > in “Search programs and files,” search for Internet Explorer> select “Internet Explorer.”
witech-wiring-diagram-not-view-4
Windows XP:
The user may see a blank page with small “Landscape” icon in the top-left corner of the page.
  1. Confirm browser is Internet Explorer (IE) 8 or higher.
  • IE 6 and 7 are not supported by DealerCONNECT
  1. Confirm Adobe SVG Viewer plug-in version 3.03is installed
  2. If Adobe SVG Viewer plug-in is installed, it has become corrupted and will need to be reinstalled.
witech-wiring-diagram-not-view-5